WELCOME TO CHANGCHUN YINGPU MAGNETOELECTRIC TECHNOLOGY DEVELOPMENT CO., LTD. OFFICIAL WEBSITE!

Address: 183 YINGXIANG EAST STREET, ERDAO DISTRICT,  CHANGCHUN,  CHINA

Contact:086-431-85562503 / 17643118999

 

Fax:0431-85235752

 

E-mail:ypsales@ccypcd.com / yptech@ccypcd.com

ALL RIGHTS RESERVED CHANGCHUN YINGPU MAGNETOELECTRIC TECHNOLOGY DEVELOPMENT CO. LTD         JI ICP XXXXX NUMBER        WEBSITE CONSTRUCTION: CHANGCHUN ENTERPRISE POWER

>
Products_detaile
Page view:

One-dimensional Helmholtz coil

Helmholtz coil has large uniform area, wide use space and easy operation. Can realize one-dimensional, two-dimensional and three-dimensional combined magnetic field, can provide alternating current and direct current magnetic fields, and has a good linear relationship between current and magnetic field. It is suitable for various research institutes, universities and enterprises to do material magnetism or testing experiments. It is applied to materials, electronics, biology, medical treatment, aerospace, chemistry, applied physics and other disciplines. Its main purpose is to generate standard magnetic fields. Cancellation and compensation of the earth's magnetic field, geomagnetic environment simulation, determination of magnetic shielding effect, electromagnetic interference simulation experiment, calibration of hall probe and various magnetometers, research of biological magnetic field and material magnetic properties
没有此类产品
产品描述

 

 

Helmholtz coil features a Larger Uniformity Volume, Greater Accessibility to the Working Gap and Easy Operation. Helmholtz coil, which is designed to realize one-axis, two-axis, three-axis and combined magnetic fields, can provide AC and DC magnetic fields, of which there is a good linear relation between the current and the magnetic field.

Helmholtz coil can be used for Magnetic Characteristic and Testing and Measuring Experiments of Materials conducted in the colleges and universities, and can be applied for Different Disciplines, such as Materials, Electronics, Biology, Medicine, Aerospace, Chemistry, Applied Physics, and etc.

Typical Application  including Standard Magnetic Field Generation, Earth’s Magnetic Field Cancellation and Compensation, Geomagnetic Environment Simulation, Active Magnetic Shielding Effects, Electromagnetic Interference Simulation Experiment, the Calibration of Hall Sensor and Different Magnetometers, Biological Magnetic Field Study and Material Magnetic Characteristic Study. Our coil can be Customer-Designed and Customer-Made according to user’s individual requirements.


 One-Axis Coil

 

One-Axis Helmholtz Coil Typical Parameters

Model No.:

Nominal Radius(mm)

Center Magnetic Field
(Gs)

Homogeneity 
%

Homogeneity Volume Sphere diametermm

Power Range Per Axis 
(W)

One-Axis Weight
(Kg)

Three-Axis Weight
Kg

HLY30-50

300

50

5

200

420

55

 

1

150

HLY30-10

300

10

0.5

100

90-120

12

38

0.1

90

HLY30-2

300

2

0.05

60

18~32

3.5

11

0.01

40

HLY25-1000

250

1000

5

160

5000

500

 

1

125

HLY25-500

250

500

0.5

100

2500

250

 

0.1

75

HLY25-300

250

300

0.05

50

1600

150

 

0.01

33

HLY25-100

250

100

5

160

600

50

 

1

125

HLY25-50

250

50

0.5

100

300~620

30

138

0.1

75

HLY25-10

250

10

0.05

50

60~110

8

32

0.01

33

HLY25-2

250

2

5

160

12~18

4

14

1

125

HLY20-500

200

500

0.5

80

2000

160

 

0.1

60

HLY20-300

200

300

0.05

40

1000

96

 

0.01

26

HLY20-100

200

100

5

130

350

32

 

1

100

HLY20-50

200

50

0.5

80

200~520

16

54

0.1

60

HLY20-10

200

10

0.05

40

40~65

8

28

0.01

26

HLY20-5

200

5

1

100

20~32

6

22

0.1

60

HLY20-2

200

2

1

100

8~10

4

15

0.1

60

HLY15-300

150

300

5

100

660

54

 

1

75

HLY15-100

150

100

0.5

60

220

18

 

0.1

45

HLY15-50

150

50

0.05

30

110~330

12

38

0.01

20

HLY15-10

150

10

1

75

21~42

6

24

0.1

45

HLY10-200

100

200

5

66

200

19

 

1

50

HLY10-100

100

100

0.5

40

100

15

 

0.1

30

HLY10-50

100

50

0.05

20

50~180

9

20

0.01

10

HLY10-10

100

10

1

50

10~24

3.5

13

0.1

30

HLY7-100

70

100

5

45

50

7

 

1

35

HLY7-50

70

50

0.5

28

24~120

5

17

0.1

21

HLY7-10

70

10

0.05

14

5~24

2

8

0.01

9.3

 
 

Item No.:

Product Name

Model No.:

Technical Parameters

Product Photos

1

One-Axis Coil

HLY10-100

Horizontal Field,

The Highest Center Magnetic Field Strength: 100 Gs,

Nominal Diameter: 200 mm,

Homogeneity Volume: Φ 30 * 30 mm,

Homogeneity: 0.1 %,

Power: 100 W.

 

2

One-Axis Coil

HLY10-10

Horizontal Field,

The Highest Center Magnetic Field Strength: 10 Gs,

Nominal Diameter: 200 mm,

Homogeneity Volume: Φ 30 * 30 mm,

Homogeneity: 0.1 %,

Power: 10 W.

3

One-Axis Coil

HLY10-200

Horizontal Field,

The Highest Center Magnetic Field Strength: 200 Gs,

Nominal Diameter: 200 mm,

Homogeneity Volume: Φ 30 * 30 mm,

Homogeneity: 0.1 %,

Power: 200 W.

4

One-Axis Coil

HLY20-10

Horizontal Field,

Adjustable Inter-Coil Spacing Distance,

The Highest Center Magnetic Field Strength: 10 Gs,

Nominal Diameter: 400 mm,

Homogeneity Volume: Φ100*1000 mm,

Homogeneity: 1 %,

Power: 40 W.

5

One-Axis Coil

HLY20-200

Horizontal Field,

The Highest Center Magnetic Field Strength: 200 Gs,

Nominal Diameter: 400 mm,

Homogeneity Volume: Φ 60 * 60 mm,

Homogeneity: 1*10-3,

Power: 700 W (10 A, 70 V)

6

One-Axis Coil

HLY50-1

Horizontal Field,

The Highest Center Magnetic Field Strength: 1.0 Gs,

Nominal Diameter: 1000 mm,

Homogeneity Volume: Φ 140 * 140 mm,

Homogeneity: 0.1 %,

Power: 40 W.

 

 

 

 

 

 

Product introduction

 

Helmholtz coil has large uniform area, wide use space and easy operation. Can realize one-dimensional, two-dimensional and three-dimensional combined magnetic field, can provide alternating current and direct current magnetic fields, and has a good linear relationship between current and magnetic field. It is suitable for various research institutes, universities and enterprises to do material magnetism or testing experiments. It is applied to materials, electronics, biology, medical treatment, aerospace, chemistry, applied physics and other disciplines. Its main purpose is to generate standard magnetic fields. Cancellation and compensation of the earth's magnetic field, geomagnetic environment simulation, determination of magnetic shielding effect, electromagnetic interference simulation experiment, calibration of hall probe and various magnetometers, research of biological magnetic field and research of material magnetic properties.

 

One-dimensional coil

 

Helmholtz coil specification parameters

Coil model

Radius (mm)

Central magnetic field
(Gs)

Uniformity
%

Diameter of sphere in uniform area (mm)

Power range per dimension
(W)

One dimensional weight
(Kg)

Three-dimensional weight
(Kg)

               
               
               
               
               
               
               
               
               

 

Corresponding parameter set not found, please add it in property template of background
暂未实现,敬请期待
暂未实现,敬请期待
Previous article
Next article