SBV type electromagnet: the magnetic field air gap is unidirectionally adjustable, the double yoke structure forms a closed magnetic circuit, has good rigidity, and the magnetic field direction is vertical; Stand upright, the sample can be placed on the plane of the lower pole head, which is convenient to take and place the sample and suitable for repeated measurement. It is widely used in Hall effect research, magnetoresistance effect research, hysteresis expansion research, torque magnetometer, force magnetometer, magnetic susceptibility measuring device, magnetic material measuring device, magnetization and demagnetization of magnetic devices, etc. In order to improve the magnetic field strength, it can also be used as an iron-bone alloy pole head, and can be used for processing uniform magnetic field pole heads and gradient magnetic field pole heads. It can process electromagnet rotating table, electromagnet shield, electromagnet matching base, bottom car, bottom box, etc.
|
Model
|
leading indicator
|
Reference picture
|
SBV-130
|
1. Structure: Electromagnet is a double yoke monotonic vertical seat, pole is unidirectionally adjustable and variable air gap, and magnetic field direction is perpendicular to the ground.2, electromagnet pole diameter is Φ130, with a pair of 60mm diameter pole head, wire spacing of 120mm, air gap adjustable range of 0~100mm .. 3. when the air gap is 10mm, the magnetic field h ≥ 2.6 t. The electromagnet internal cooling type water cooling structure can last for 30 minutes when the magnetic pole spacing is 25mm and the magnetic field is 1.7T; Scanning magnetic field can work for a long time. 4. magnetic field uniformity: when the magnetic field is 15mm air gap, the magnetic field uniformity is better than 0.1% in the area with the center φ 10 * 10 mm3. 5. The wire wrap resistance is 5.0 ohms and the rated power supply power is 3.0KW
|

|
SBV-200
|
1. Structure: Electromagnet is a double yoke monotonic vertical seat, pole is unidirectionally adjustable and variable air gap, and magnetic field direction is perpendicular to the ground. 2, electromagnet pole diameter is Φ200mm, pole head diameter is 80mm, wire wrap spacing is 120mm, air gap adjustable range 0~100mm .. 3. when the air gap is 10mm, the magnetic field h ≥ 2.8 t. When the distance between magnetic poles is 30mm and the magnetic field is 2.3T, the electromagnet internal cooling type water cooling structure can work continuously for 10 minutes. Scanning magnetic field can work for a long time. 4. magnetic field uniformity: when the magnetic field is 20mm air gap, the magnetic field uniformity is better than 0.1% in the area with the center φ 10 * 10 mm3. 5. The wire wrap resistance is 5.0 ohms and the rated power supply power is 8.0KW
|

|
SBV-250
|
1. Structure: Electromagnet is a double yoke monotonic vertical seat, pole is unidirectionally adjustable and variable air gap, and magnetic field direction is perpendicular to the ground. 2, electromagnet pole diameter is Φ250mm, pole head diameter is 120mm, wire spacing is 120mm, air gap adjustable range of 0~100mm .. 3. when the air gap is 10mm, the magnetic field h ≥ 2.6 t. The electromagnet internal cooling type water cooling structure can last for 10 minutes when the magnetic pole spacing is 30mm and the magnetic field is 2.2T T.: Scanning magnetic field can work for a long time. 4. Magnetic field uniformity: When the magnetic field is 20mm air gap, the magnetic field uniformity is better than 0.1% in the area with a center Φ20*20mm3 5. The wire wrap resistance is 5.0 ohms and the rated power supply power is 10.0KW
|
|
|